immagine

Dynamic Application

PMXX®️ PLUS

SERVO WITH TRIPLET

Applicative Features

image
Up to 5 million cycle
Guaranteed Cycles
50,0 m/s2
Acceleration
15,0 m
Cable length
300,0 m/min
Travel speed
Minimum Bending radius
Cross Section Cross section max Dynamic Installation Static installation
0.50 16.00 7xØ 4xØ

Approvals

Certification image not found

AWM STYLE 21209 90°C 1000V

Certification image not found

AWM I/II A/B 90°C 1000V

Certification image not found

2014/35/CEE

Certification image not found

2014/30/EU

Certification image not found

2011/65/UE

Certification image not found

1907/2006

Certification image not found

IEC 60754-1

EN 50267-1

Technical data

image
storage

-50°C +80°C

dynamic

-30°C +90°C

static

-40°C +90°C

image
Nominal voltage

1000 V

image
Test Voltage

4,0 kV

Test Voltage Reference

EN 50395 part 6-7 - UL/1581

image
Insulation resistance

≥1 Gohm/Km(20°C)

≥10 Mohm/Km(90°C)

Construction features

Power conductors

Conductor

CL6 Extra-flexible.

Bare copper.

Insulation

Polypropylene compound (PP)

Insulation Color

Black core with white printing ( U/L1/C/L+

V/L2

W/L3/D/L-) +

Green-Yellow.

separationLayer

Inner tape

Polyester transparent tape or non-woven tape

Control Triplet Screened

Conductor

CL6 Extra-flexible.

Bare copper.

Insulation

Polypropylene compound (PP)

Insulation Color

Black core with white printed numbers.

filler

Filler

Polypropylene

separationLayer

Intermediate tape

Non-woven tape

screen

Inner screen

Tinned copper

85 % ± 5 %

separationLayer

Intermediate tape

Non-woven tape

Overall Stranding

filler

Filler

Polypropylene

separationLayer

Tape

Non-woven tape

screen

Screen

Tinned copper

85 % ± 5 %

separationLayer

Tape

Non-woven tape

Sheath

Polyurethane

compound (TMPU)

Sheath Colour Orange, RAL: 2003, desina: yes

Products features

image

Fire performance

Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2

DIN EN 60332-1-2

IEC 60332-1-2

UL 1581 sec.1061 Cable flame

UL VW-1

CSA FT1

image

Oil performance

VDE 0207-363-10-2

IEC 60811-404 (EU)

CEI EN 50363-10-2

1581 (UL)

image

Uv performance

according to ISO 4892-2

EN 50289-4-17

ASTM-D-2565-16

EN 50618

image

Water performance

UL 1581

IEC 60811-1-3

EN 50396 (Hydrolyses Resistance)

image

cold Performance

EN60811-1-4

image

Abrasion performance

ASTM D 4060

image

Mud performance

Nek TS 606

IEC 60092-360 Annex C+D

image

Microbe performance

VDE 0282/10

image

Hozone performance

EN 50396 art. 8.1.3

teco code Oem ref. N° cores x cross-section cut rolls [M] drums [M] Ext Ø [mm] Weight [kg/km]

43309

SEW

[4G1,50+(3x1,00)ST]ST

[4GAWG16+(3xAWG18)ST]ST

500

11.8

220

43310

SEW

[4G2,50+(3x1,00)ST]ST

[4GAWG14+(3xAWG18)ST]ST

500

13.4

280

43311

SEW

[4G4,00+(3x1,00)ST]ST

[4GAWG12+(3xAWG18)ST]ST

14.8

350

43312

SEW

[4G6,00+(3x1,50)ST]ST

[4GAWG10+(3xAWG16)ST]ST

17

530

43313

SEW

[4G10,00+(3x1,50)ST]ST

[4GAWG08+(3xAWG16)ST]ST

19.8

800