technical data sheet

part number

11257H

cable family

O.R. FE-ST  

Formation: [3x(2x0,14)SF/R+2x(0,50)SF/R]ST/PUR Article no longermanaged

[3x(2xAWG26)SF/R+2x(AWG21)SF/R)]ST

installation type: CABLE FOR STATIC INSTALLATION

category: ENCODER / RESOLVER

standard/approval: CE/UL/CSA

shielding: SHIELDED

UL RECOGNIZED E244280CSAHalogen FreeCERoHS2014/30/EU

group 1 // 3x(2x0,14)

conductor
material Tinned copper
capillary diameter - Flexible (DIN VDE 0295, IEC 60228 o CEI 20-29)
conductors number 6
rated section 0,14 mm²
insulation
material Polyolefin
colour Yellow-Green, Blue-Red, Grey-Pink.
intermediate taping
make-up Around each pair.
material Polyester tape
shield
on make-up On each taped pair.
material Tinned copper
shield shape Wrapped shield
coverage >=97
drain wire Not available
sheath
make-up On each shielded pair.
material PVC
colour White - RAL 9010

group 2 // 1x0,50

conductor
material Tinned copper
capillary diameter - Flexible (DIN VDE 0295, IEC 60228 or CEI 20-29)
conductors number 1
rated section 0,50 mm²
insulation
material Polyolefin
colour Brown
shield
on make-up On the conductor.
material Tinned copper
shield shape Wrapped shield
coverage >=97
drain wire Not available
sheath
make-up On the shield.
material PVC
colour Brown - RAL 8003

group 3 // 1x0,50

conductor
material Tinned copper
capillary diameter - Flexible (DIN VDE 0295, IEC 60228 or CEI 20-29)
conductors number 1
rated section 0,50 mm²
insulation
material Polyolefin
colour White
shield
on make-up On the conductor.
material Tinned copper
shield shape Wrapped shield
coverage >=97
drain wire Not available
sheath
make-up On the shield.
material PVC
colour White - RAL 9010

total assembly make-up

intermediate taping
on make-up Around the total assembly.
material Polyester tape
total shield
on make-up On the tape.
material Tinned copper
shield shape Braid shield
coverage >=85 %
drain wire Not available
total taping
on make-up On the shield.
material Non-woven tape
total sheath
material Polyurethane non-abrasive
colour Green RAL 6018 DESINA ®
diameter (mm) 8.5±0.35
Marking
Metric marking P/N 11257H TE.CO. E244280 - Fxx - cRUus - AWM STYLE 20549 80°C 300V- AWM I/II A/B 80°C 300V FT1 - [3x(2xAWG26)H1+2x(AWG21)H1]H2 - O.R. FE-ST [3x(2x0,14)H1+2x(0,5)H1]H2 - IEC 60332-1-2 - year/week - DESINA® - CE meter indication
electrical features
working voltage 300 V
test voltage 2000 V
rated capacity (AWG26)(c/c) <=75 pF/m; (c/s) <=128 pF/m; (AWG21)(c/c) <=50pF/m; (c/s) <=208 pF/m
electrical resistance (AWG26) <=140 ohm/km; (AWG21) <=43,6 ohm/km
insulation resistance <1 Gohm/km
dynamic features
minimum bending radius static installation 6 times ø cable
working temperature static installation -40°C / +80°C
installation temperature text -5°C / +80°C
notes For fixed installation without any mechanical stress.
approvals and standards
reference standards 1581, UL 758(UL); C22.2 n° 210(CSA)
ul csa approvals RU E244280 AWM STYLE 20549 80°C 300V CSA E244280 AWM I/II A/B 80°C 300V
fire behaviour FT1(CSA); IEC 60332-1-2(EU)
industrial oil resistance 1581(UL); IEC 60811-404/507(EU); IRM 902
halogen free SI
compatibility
wiring/manufacturer Heidenhain
Customs code
Customs-tariff number 85444995
Made in IT
TE.CO. reserves the right to make some modifications to the products notwithstanding the basic technical characteristics. Unless otherwise stated, all indicated data are nominal. RAL colour is stated only as reference. TE.CO. Tecnologia Commerciale S.p.A. – Via Achille Grandi, 1 – 40013 Castel Maggiore (Bologna – Italia) – Tel +39 051 6047311 Web: www.tecoit.com – E-mail: sales@tecoit.com – Reg. Impr. Bologna e Codice Fiscale 03163100377 – P.IVA IT 01636081208. Subject to management and coordination activities handled by Pronos S.r.l.. All rights are reserved. The reproduction of any part of this document is not allowed without the written authorization of TE.CO. Tecnologia Commerciale S.p.A..