technical data sheet

part number

11337

cable family

Profibus®  

Formation: (1x2xAWG22/1)SN/ST

installation type: CABLE FOR STATIC INSTALLATION

category: PROFIBUS®

standard/approval: CE/UL/CSA

shielding: SHIELDED

UL RECOGNIZED E244280CSACERoHS2014/30/EUPROFI BUS

group // 1x2xAWG22

conductor
material Bare copper
capillary diameter - Solid
conductors number 2
rated section AWG22 AWG
insulation
material Foam polyolefin
colour Green, Red.

total assembly make-up

intermediate taping
on make-up Around the total assembly. (optional)
material Polyester tape
total shield
on make-up On the tape. Aluminium outside
material Aluminium/polyester tape
shield shape Overlapped shielding tape
coverage >100 %
drain wire Not available
total shield external
on make-up On the tape shield.
material Tinned copper
shield shape Braid shield
coverage 65 %
drain wire Not available
total taping
on make-up On the shield.(Optional)
material Non-woven tape
total sheath
material PVC
colour Violet RAL 4001 DESINA ®
diameter (mm) 8±0.25
Marking
Metric marking P/N 11337 - TE.CO. E244280 - Fxx - cRUus - AWM STYLE 2571 80°C VW-1 - AWM I/II A/B 80°C 300V FT1 - PROFIBUS - CONTROL DATA - BUS - DP - F.I.P. - 150 ohm - (1x2x0,64ø)H/H2 - O.R. UE (1x2xAWG22)H/H2 - year/week - batch - DESINA® - CE meter indication
electrical features
working voltage 300 V
test voltage 2000 V
rated capacity <=30 pF/m
rated impedance 150±10% ohm
electrical resistance <=55,4 ohm/km
insulation resistance 5 Gohm/km
transmission speed Up to 12Mbit/s
propagation speed 77%
attenuation *** PROFIBUS® DP*** ATTENUATION Frequency[MHz]/Attenuation.std(dB/100m)/attenuation.typical[ 0,0096/0,25/--/ - 0,0384/0,4/--/ - 4/2,2/--/ - 16/4,2/--/ - MAXIMUM ATTENUATION: 9,6kHz = 0,25dB/100m; 38,4kHz = 0,4dB/100m; 4MHz = 2,2dB/100m; 16MHz = 4
dynamic features
minimum bending radius static installation 10 times ø cable
working temperature static installation -30°C / +80°C
installation temperature text -5°C / +80°C
notes For fixed installation without any mechanical stress.
approvals and standards
reference standards 1581, UL 758(UL); C22.2 n° 210(CSA); DIN EN 61784-1, DIN EN 61158; NETBUS L2/F.I.P.(Factor,Instrumentation,Protocol), PROFIBUS® DP (DIN 19245), RS 485
ul csa approvals RU E244280 AWM STYLE 2571 80°C CSA E244280 AWM I/II A/B 80°C 300V
fire behaviour VW-1(UL); FT1(CSA); IEC 60332-1-2(EU)
industrial oil resistance 1581(UL); IEC 60811-404(EU); CEI EN 50363-4-1(EU); ICEA S-82-552; IRM 902
halogen free NO
compatibility
wiring/manufacturer Siemens / 6XV1830-0EH10
Customs code
Customs-tariff number 85444995
Made in IT
TE.CO. reserves the right to make some modifications to the products notwithstanding the basic technical characteristics. Unless otherwise stated, all indicated data are nominal. RAL colour is stated only as reference. TE.CO. Tecnologia Commerciale S.p.A. – Via Achille Grandi, 1 – 40013 Castel Maggiore (Bologna – Italia) – Tel +39 051 6047311 Web: www.tecoit.com – E-mail: sales@tecoit.com – Reg. Impr. Bologna e Codice Fiscale 03163100377 – P.IVA IT 01636081208. Subject to management and coordination activities handled by Pronos S.r.l.. All rights are reserved. The reproduction of any part of this document is not allowed without the written authorization of TE.CO. Tecnologia Commerciale S.p.A..