technical data sheet

part number

24204

cable family

O.R. PMXX-ST®  

Formation: (2x2xAWG26)ST

(2x2x0,14)ST

installation type: CABLE FOR DYNAMIC INSTALLATION ON DRAG CHAIN

category: ENCODER / RESOLVER

standard/approval: CE/UL/CSA

shielding: SHIELDED

UL RECOGNIZED E244280CSACERoHS2014/30/EU

group // 2x2xAWG26

conductor
material Bare copper
capillary diameter - Extra-flexible (DIN VDE 0295, IEC 60228 or CEI 20-29)
conductors number 4
rated section AWG26 AWG
insulation
material PVC
colour DIN 47100: White-Brown, Green-Yellow.

total assembly make-up

intermediate taping
on make-up Around the total assembly.
material Non-woven tape
total shield
on make-up On the tape.
material Tinned copper
shield shape Braid shield
coverage >=85 %
drain wire Not available
total taping
on make-up On the shield.
material Non-woven tape
total sheath
material Polyurethane non-abrasive
colour Green RAL 6018 DESINA ®
diameter (mm) 5.6±0.25
Marking
Metric marking P/N 24204 TE.CO. E244280 - Fxx - cRUus - AWM STYLE 20233 80°C 300V - AWM I/II A/B 80°C 300V FT1 - (2x2xAWG26)H2 - O.R. PMXX-ST® (2x2x0,14)H2 - IEC 60332-1-2 - year/week - DESINA® - CE meter indication
electrical features
working voltage 300 V
test voltage 2000 V
rated capacity (c/c) <=130 pF/m
electrical resistance <=140 ohm/km
propagation speed 49%
dynamic features
minimum bending radius static installation 4 times ø cable
minimum bending radius dynamic installation 7.5 times ø cable
working temperature static installation -40°C / +80°C
working temperature dynamic installation -10°C / +80°C
travel speed Up to 180 m/min
acceleration/deceleration Up to 10 m/sec²
cable length inside chain Up to 15 m
chain length notes (horizontal only)
guaranteed cycles Up to 5 Mio
torsions Contact our technical department
notes The given data are meant to be restricted to the type of reference installation. For fixed installation is meant to be without any mechanica stress. For application in dynamic installation with very low temperatures, contact our technical department.
approvals and standards
reference standards 1581, UL 758(UL); C22.2 n° 210(CSA)
ul csa approvals RU E244280 AWM STYLE 20233 80°C 300V CSA E244280 AWM I/II A/B 80°C 300V
fire behaviour FT1(CSA); IEC 60332-1-2(EU) HALOGEN FREE: NO HALOGEN
industrial oil resistance 1581(UL); IEC 60811-404(EU); CEI EN 50363-10-2(EU); IRM 902
halogen free NO
UV resistance UV RESISTANT
compatibility
wiring/manufacturer CONTROL TECHNIQUES
Customs code
Customs-tariff number 85444995
Made in IT
TE.CO. reserves the right to make some modifications to the products notwithstanding the basic technical characteristics. Unless otherwise stated, all indicated data are nominal. RAL colour is stated only as reference. TE.CO. Tecnologia Commerciale S.p.A. – Via Achille Grandi, 1 – 40013 Castel Maggiore (Bologna – Italia) – Tel +39 051 6047311 Web: www.tecoit.com – E-mail: sales@tecoit.com – Reg. Impr. Bologna e Codice Fiscale 03163100377 – P.IVA IT 01636081208. Subject to management and coordination activities handled by Pronos S.r.l.. All rights are reserved. The reproduction of any part of this document is not allowed without the written authorization of TE.CO. Tecnologia Commerciale S.p.A..