technical data sheet

part number

46692

cable family

O.R. PMXX-ST® PLUS  

Formation: [4x(2x0,25)ST/R]ST

[4x(2xAWG24)ST/R]ST

installation type: CABLE FOR DYNAMIC INSTALLATION ON DRAG CHAIN

category: ENCODER / RESOLVER

standard/approval: CE/UL/CSA

shielding: SHIELDED

UL RECOGNIZED E244280CSAHalogen FreeCERoHS2014/30/EU

group // 4x(2x0,25)

conductor
material Tinned copper
capillary diameter - Extra-flexible (DIN VDE 0295, IEC 60228 or CEI 20-29)
conductors number 8
rated section 0,25 mm²
insulation
material Polyolefin
colour White-Yellow, White-Blue, White-Red, White-Green.
intermediate taping
make-up Around each pair.
material Polyester tape
shield
on make-up On each taped pair.
material Tinned copper
shield shape Braid shield
coverage >=85
drain wire Not available
sheath
make-up On each shielded pair.
material Polyolefin
colour Matte black - RAL 9005

total assembly make-up

intermediate taping
on make-up Around the total assembly.
material Non-woven tape
total shield
on make-up On the tape.
material Tinned copper
shield shape Braid shield
coverage >=85 %
drain wire Not available
total taping
on make-up On the shield.
material Non-woven tape
total sheath
material Polyurethane non-abrasive
colour Green RAL 6018 DESINA ®
diameter (mm) 9.2±0.4
Marking
Metric marking P/N 46692 TE.CO. E244280 - Fxx - cRUus - AWM STYLE 21209 90°C 300V VW-1 - AWM I/II A/B 90°C 300V FT1 - (4x(2x24AWG)) - O.R. PMXX-ST® [4x(2x0,25)SH]SH - IEC 60332-1-2 - year/week - DESINA® - CE meter indication
electrical features
working voltage 300 V
test voltage 2000V; c/c c/all. screen 2000Vrms,1min V
rated capacity c/c 70 nF/Km (800 Hz); c/s 100nF/Km (800 Hz) pF/m
rated impedance Max 250 Ohm/m (30 MHz) ohm
insulation resistance >=1 Gohm/Km acc.to EN 50395 prt.8 (90°C)
additional note BRAIDED RESISTANCE
additional note text Max 250 ohm/Km (at 30 MHz)
dynamic features
minimum bending radius static installation 5 times ø cable
minimum bending radius dynamic installation 7 times ø cable
working temperature static installation -40°C / +90°C
working temperature dynamic installation -30°C / +90°C
travel speed Up to 300 m/min
acceleration/deceleration Up to 50 m/sec²
cable length inside chain Up to 25 m
chain length notes (horizontal only)
guaranteed cycles Up to 5 Mio
torsions ±30°/m
notes The given data are meant to be restricted to the type of reference installation. For fixed installation is meant to be without any mechanica stress. For application in dynamic installation with very low temperatures, contact our technical department.
approvals and standards
reference standards 1581, UL 758(UL); C22.2 n° 210(CSA); Referring to DIN VDE 0207,0285,0819 and 0295.
ul csa approvals RU E244280 AWM STYLE 21209 90°C 300V CSA E244280 AWM II A/B 90°C 300V
fire behaviour VW-1(UL); FT1(CSA); IEC 60332-1-2(EU); DIN VDE 0482-332-1-2; DIN EN 60 332-1-2; UL CABLE FLAME HALOGEN FREE: IEC 60754-1(EU); EN 50267-1(EU)
industrial oil resistance 1581(UL); IEC 60811-404(EU); CEI EN 50363-10-2(EU); VDE 0473-811-404
halogen free SI
UV resistance ASTM ASTM-D-2565-16; EN 50289-4-17(EU); ISO 4892-2
Customs code
Customs-tariff number 85444995
Made in IT
TE.CO. reserves the right to make some modifications to the products notwithstanding the basic technical characteristics. Unless otherwise stated, all indicated data are nominal. RAL colour is stated only as reference. TE.CO. Tecnologia Commerciale S.p.A. – Via Achille Grandi, 1 – 40013 Castel Maggiore (Bologna – Italia) – Tel +39 051 6047311 Web: www.tecoit.com – E-mail: sales@tecoit.com – Reg. Impr. Bologna e Codice Fiscale 03163100377 – P.IVA IT 01636081208. Subject to management and coordination activities handled by Pronos S.r.l.. All rights are reserved. The reproduction of any part of this document is not allowed without the written authorization of TE.CO. Tecnologia Commerciale S.p.A..