Cross section min (mm2) | Cross section max (mm2) | Dynamic Installation | Static installation |
---|---|---|---|
0.34 | 0.34 | 10.0xØ (Occ. Flexing) | 4.0xØ |
UL/CSA certified flexible data cables for use as a signal and measuring cable in machine tools, assembly lines, conveyor belts, plant construction, air conditioning devices, metallurgical plants and steel mills. Excellent rating temperature covered.
-5 °C +80 °C
static-40 °C +105 °C
Occasional Flexing-5 °C +105 °C
600 V
2 kV
Test Voltage ReferenceEN 50395-6-7
UL1581
Signal conductors |
|
---|---|
Conductor | CL5 Flexible. Tinned Copper |
Insulation | PVC compound. |
Insulation Color | Colours sequence refers to DIN 47100 standard |
Overall Stranding |
|
---|---|
filler |
Filler Not hygroscopic |
TALC |
TALC powder |
Sheath | PVC compound. |
Sheath Colour | Gray, RAL: 7001, desina: no |
Fire performance
DIN VDE 0482-332-1-2
DIN EN 60332-1-2
IEC 60332-1-2
VW-1 (UL)
FT1 (CSA)
Oil performance
VDE 0473-811-404
IEC 60811-404
UL 1581
TECO code | n° cores x cross-section | cut | rolls (m) | drums (m) | Ext Ø (mm) | Weight (kg/km) |
---|---|---|---|---|---|---|
13455 |
2x0,34 2xAWG22 |
100 |
500 |
7.2 |
65 |
|
13456 |
3x0,34 3xAWG22 |
100 |
500 |
7.8 |
78 |
|
13457 |
4x0,34 4xAWG22 |
100 |
500 |
8.3 |
90 |
|
13458 |
6x0,34 6xAWG22 |
100 |
500 |
9.8 |
110 |