immagine

dynamic application

FRX®️ PLUS

SINGLE CORE SHIELDED (SH)

Applicative Features

image
5 Million
Guaranteed Cycles
10,0 m/s²
Acceleration
15,0 m
Cable length
180,0 m/min
Travel speed
Minimum Bending radius
Cross section min (mm2) Cross section max (mm2) Dynamic Installation Static installation
4.00 16.00 7.5xØ 4.0xØ
25.00 240.00 10.0xØ 6.0xØ

Description

UL/CSA certified flexible single core power and control cables, designed for dynamic drag chains and automatic machinery applications with free movement without tensile stress or forced movements in dry or moist environment. Suitable for indoor and outdoor use. This type of cables can be a smart alternative to multicore power cables in case space or minimum bending radius requirements are challenging. Screening from electromagnetic interferences thanks to the dense braid shield.

Approvals

Certification image not found
AWM STYLE 10678 90°C 1000V
Certification image not found
AWM I/II A/B 90°C 1000V
Certification image not found
2014/35/CEE
Certification image not found
2014/30/EU
Certification image not found
2011/65/UE
Certification image not found
1907/2006

Technical data

image
dynamic

-5 °C +90 °C

static

-40 °C +90 °C

image
Nominal voltage

1000 V (UL/CSA)

uo/U 0,6/1 kV (VDE)

image
Test Voltage

4,0 kV

Test Voltage Reference

EN 50395-6-7

UL 1581

image
Insulation resistance

≥ 1 Gohm/Km

Construction features

POWER CONDUCTORS

Conductor

CL6 Extra-flexible. Bare Copper

Insulation

Polypropylene compound (PP)

Insulation Color

Black RAL 9005 or Green-Yellow

SEPARATION LAYER

INNER TAPE POLYESTER TRANSPARENT OR NON-WOVEN TAPE

Overall Stranding

screen

Screen Tinned Copper 85 % ± 5 %

SEPARATION LAYER

Tape Non-woven tape

Sheath

PVC compound.

Sheath Colour

Matte Black, RAL: 9005, desina: no

Products features

image

Fire performance

DIN VDE 0482-332-1-2

DIN EN 60332-1-2

IEC 6033-1-2

UL cable flame

VW-1 (UL)

FT1 (CSA)

image

Oil performance

VDE 0473-811-404

IEC 60811-404

CEI EN 50363-4-1

UL 1581

image

Uv performance

CEI EN 50289-4-17

ISO 4892-2

ASTM-D-2565-16

image

Water performance

UL 1581

IEC 60811

image

Hydrocarbons performance

UL 1581

TECO code n° cores x cross-section cut rolls (m) drums (m) Ext Ø (mm) Weight (kg/km)

46459

(1x6,00)ST

(1xAWG10)ST

100

500

7.2

120

46462

(1x25,00)ST

(1xAWG25)ST

500

11.4

350

46463

(1x35,00)ST

(1xAWG02)ST

500

13.3

475

46464

(1x50,00)ST

(1xAWG01)ST

15.6

700

46465

(1x70,00)ST

(1xAWG2/0)ST

17.6

870

46466

(1x95,00)ST

(1xAWG3/0)ST

20

1240

46467

(1x120,00)ST

(1xAWG4/0)ST

22.6

1450

46468

(1x150,00)ST

(1x250KCMIL)ST

24.4

1690

46469

(1x185,00)ST

(1x350Kcmil)ST

26.8

2340