Dynamic Application

PMXX®️

ETHERNET 1000V cat.6 CMX

Applicative Features

10 m/sec²
Acceleration
15 m
Cable length
200 m/min
Travel speed
Minimum Bending radius
Cross Section Cross section max Dynamic Installation Static installation
10.0xØ 7.5xØ

Approvals

Certification image not found

Type CMX 75°C 300V

Certification image not found

AWM STYLE 21576 80°C 1000V

Certification image not found

AWM I/II A/B 80°C 1000V

Certification image not found

2014/35/CEE

Certification image not found

2014/30/EU

Certification image not found

2011/65/UE 

2015/863/UE 

Certification image not found

IEC 60754-1

Technical data

image
dynamic -40°C +80°C
static -50°C +80°C
image
Nominal voltage 1000V (RU); 300V (UL)
Max operating voltage 100V EN 50288-5-1 / 5-2
image
Test Voltage 1000V (EU); 3000V (UL)
Test Voltage Reference acc.to IEC 61156-5, EN 50288-5-1 / 5-2 (EU)
image
Insulation resistance >1 Gohm/km

Construction features

Group 1
Conductor

CL6 Extra-flexible.

Bare copper.

Insulation

Expanded polyethylene (PEE)

Insulation Color

Orange-White/Orange*, Green-White/Green*,      

Blue-White/Blue*, Brown-White/Brown*.          

*Ring bicolor.                                 

Solid separation

PVC compound.

Overall stranding
separationLayer Shield Tape

Mylar inside - Alluminium outside

screen Shield braid

Tinned copper

85 % ± 5 %
separationLayer Tape

Non-woven tape

Sheath

Polyurethane compound (TMPU)

Sheath Colour

Green

, RAL: 6016, desina: no

Products features

image

Fire performance

VW-1(UL); FT2(CSA); IEC 60332-1-2(EU)

image

Oil performance

VDE 0473-811-404, IEC 60811-404, (EU) CEI EN 50363-10-2, 1581 (UL)

image

Uv performance

according to ISO 4892-2, EN 50289-4-17, ASTM-D-2565-16

image

Hydrocarbons performance

EN 50267-2-1

teco code Oem ref. Formation cut rolls [M] drums [M] Ext Ø [mm] Weight [kg/km]
38736 SIEMENS 6XV1878-2C/B

(4x2xAWG26)SN/ST

100 500/1000 7.2 64