Dynamic Application

PMXX®️ PLUS

SIGNAL

Applicative Features

image
Up to 5 million
Guaranteed Cycles
30,0 m/s2
Acceleration
15,0 m
Cable length
300,0 m/min
Travel speed
Minimum Bending radius
Cross Section Cross section max Dynamic Installation Static installation
0.14 1.00 6xØ 4xØ

Approvals

Certification image not found

AWM STYLE 21209 90°C 300V

Certification image not found

AWM I/II A/B 90°C 300V

Certification image not found

2014/35/CEE

Certification image not found

2011/65/UE

Certification image not found

1907/2006

Certification image not found

IEC 60754-1

EN 50267-1

Technical data

image
storage -50°C +90°C
dynamic -30°C +90°C
static -40°C +90°C
image
Nominal voltage 300 V (UL/CSA) 300 V (VDE)
image
Test Voltage 2,0 kV
image
Insulation resistance ≥1 Gohm/Km

Construction features

Signal conductors
Conductor

CL6 Extra-flexible.

Bare copper.

Insulation

Polypropylene compound (PP)

Insulation Color

Colours sequence refers to DIN 47100 standard.
 

Overall Stranding
filler Filler

Polypropylene

separationLayer Tape

Non-woven tape

Sheath

Polyurethane compound (TMPU)

Sheath Colour

Gray

, RAL: 7001, desina: no

Products features

image

Fire performance

Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2, UL Cable flame, UL VW-1, CSA FT1.
image

Oil performance

VDE 0473-811-404 IEC 60811-404 (EU) CEI EN 50363-10-2 (EU) 1581 (UL)

image

Uv performance

according to ISO 4892-2, EN 50289-4-17, ASTM-D-2565-16
image

Water performance

UL 1581 - IEC 60811-1-3
image

cold Performance

EN60811-1-4
image

Abrasion performance

ASTM D 4060
image

Mud performance

Nek 606
image

Microbe performance

VDE 0282/10
image

Hozone performance

EN 50396 art. 8.1.3
teco code Formation cut rolls [M] drums [M] Ext Ø [mm] Weight [kg/km]
46680

7x0,34

7xAWG22

100/200 500 6.4 55