Dynamic Application

PMXX®️ PLUS

ENCODER&RESOLVER 10

Applicative Features

image
Up to 5 million cycles
Guaranteed Cycles
Up to 50 m/s2
Acceleration
Up to 25,0 m
Cable length
Up to 300 m/min
Travel speed
Minimum Bending radius
Cross Section Cross section max Dynamic Installation Static installation
0.14 1.00 7.0xØ 5.0xØ

Approvals

Certification image not found

AWM STYLE 21209 90°C 300V

Certification image not found

AWM I/II A/B 90°C 300V

Certification image not found

2014/35/CEE

Certification image not found

2014/30/EU

Certification image not found

2011/65/UE

Certification image not found

1907/2006

Certification image not found

IEC 60754-1

EN 50267-1

Technical data

image
storage - 50°C + 90°C
dynamic - 30°C + 90°C
static - 40°C + 90°C
image
Nominal voltage 300 V (UL/CSA)
image
Test Voltage c/c 2000Vrms,1min, c/overall screen 2000Vrms,1min
image
Insulation resistance ≥1 Gohm/Km

Construction features

Group 1
Conductor

CL6 Extra-flexible.

Tinned copper

Insulation

Polypropylene compound (PP)

Insulation Color

Colours sequence refers to DIN 47100 standard.
 

drainWire Drain wire

Tinned copper

separationLayer Wrapping tape screen

Alluminium inside/Polyester outside

separationLayer Tape

Polyester transparent.

Group 2
Conductor

CL6 Extra-flexible.

Tinned copper

Insulation

Polypropylene compound (PP)

Insulation Color

Colours sequence refers to DIN 47100 standard.
 

Group 3
Conductor

CL6 Extra-flexible.

Tinned copper

Insulation

Polypropylene compound (PP)

Overall stranding
separationLayer Wrapping

Non-woven tape

screen Screen

Tinned copper

85 % ± 5 %
separationLayer Overall Wrapping

Non-woven tape

Sheath

Polyurethane compound (TMPU)

Sheath Colour

Green

, RAL: 6018, desina: yes

Products features

image

Fire performance

Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2, UL Cable flame, UL VW-1, CSA FT1

image

Oil performance

VDE 0473-811-404, IEC 60811-404(EU), CEI EN 50363-10-2(EU), 1581(UL)

image

Uv performance

ISO 4892-2, ASTM-D-2565-16, EN 50289-4-17

image

Water performance

UL 1581, IEC 60811-1-3

image

cold Performance

EN 60811-1-4

image

Abrasion performance

ASTM D 4060

image

Mud performance

NEK 606

image

Microbe performance

VDE 0282/10

image

Hozone performance

EN 50396 Art. 8.1.3

teco code Formation cut rolls [M] drums [M] Ext Ø [mm] Weight [kg/km] Ins. colour exc
46703

[(2x0,34)ccSN+6x2x0,34+2x1,00]ST

[(2xAWG22)ccSN+6x2xAWG22+2xAWG18]ST

500 11 198 Group 1 2x0,34 : WH-BN Group 2 6x2x0,34 : GN-YE, GY-PK, BU-RD, BK-VT, WH/GN*-BN/GN*, GY/PK*-RD/BU* Group 3 2x1,00 : RD-BU *Ringed bicolour