Cross section min (mm2) | Cross section max (mm2) | Dynamic Installation | Static installation |
---|---|---|---|
0.22 | 0.22 | 6.0xØ |
UL/CSA certified flexible cables for industrial devices that work with the INTERBUS® data transmission standard, designed for Static application between the central controlling unit and the input/output peripheral components. The construction of these cables is designed to limit electromagnetic interference for optimal and clean communication.
-5 °C +80 °C
static-30 °C +80 °C
30 V
500 V
100 ± 15 % ohm
Twisted pair |
|
---|---|
Conductor | CL5 Flexible. Bare Copper |
Insulation | Polyethylene compound (PE) |
Overall Stranding |
|
---|---|
filler |
Filler Polypropylene |
SEPARATION LAYER |
Tape polyester PET - Polyester. |
screen |
SHIELDED TAPE MYLAR/ALLUMINIUM 100 % ± 5 % |
screen |
Shield braid Tinned Copper 85 % ± 5 % |
SEPARATION LAYER |
Tape Non-woven tape |
Sheath | PVC compound. |
Sheath Colour | Green, RAL: 6017, desina: no |
Fire performance
FT1 (CSA)
IEC 60332-1-2
Oil performance
UL 1581
IEC 60811-404
IRM 902
TECO code | n° cores x cross-section | Capacitance (nF/Km) | cut | rolls (m) | drums (m) | Ext Ø (mm) | Weight (kg/km) | Ins. colour exc |
---|---|---|---|---|---|---|---|---|
13194 |
(3x2x0,22)SN-ST (3x2xAWG24)SN/ST |
60 |
100 |
500 |
7 |
65 |
Green-Yellow, White-Brown, Pink-GRAY. |