Cross section min (mm2) | Cross section max (mm2) | Dynamic Installation | Static installation |
---|---|---|---|
0.14 | 1.50 | Occ. Flexing 10 x Ø | 6.0xØ |
Suitable for static or flexible applications with free movement, without tensile stress and forced motion control in dry, damp, and wet environments, however, not suitable for outdoor use. Favourable crosstalk attenuation values are achieved because of the pairs' twisted stranding. Even interference through parallel running cables is suppressed due to the dense braided screen assisted by the drain wire, making these cables optimal when used in systems with a risk of interference radiation.
-40 °C +80 °C
Occasional Flexing-5 °C +80 °C
350 V (not for power applications)
(C/C)
1200 V (C/S)
800 V
> 20 GOhm/cm
~ 78.0 ohm
Inductance 0,65 mH/Km
Mutual capacitance @ 800Hz (C/C)
0,14 mm² <
100 pF/m
0,25mm² <
150 pF/m
Mutual capacitance @ 800Hz (C/S)
0,14 mm² <
240 pF/m
0,25 mm² <
270 pF/m
Pairs |
|
---|---|
Conductor | CL5 Flexible. Bare Copper |
Insulation | PVC compound. |
Insulation Color | Colours sequence refers to DIN 47100 standard |
Overall Stranding |
|
---|---|
filler |
Filler Not hygroscopic |
SEPARATION LAYER |
Tape Polyester transparent. |
DRAIN WIRE |
Drain wire Tinned Copper |
screen |
Shield Tinned Copper 85 % ± 5 % |
Sheath | PVC compound. |
Sheath Colour | Gray, RAL: 7001, desina: no |
Fire performance
IEC EN 60332-1-2
DIN VDE 0482-332-1-2
Oil performance
EN 50290-2-22
TM54 CEI 20-34/0-1 4 h @ 70 °C oil IRM 902
VDE 0819-102
TECO code | n° cores x cross-section | cut | rolls (m) | drums (m) | Ext Ø (mm) | Weight (kg/km) |
---|---|---|---|---|---|---|
21234 |
(1x2x0,25)ST |
500 |
4.2 |
45 |
||
21235 |
(2x2x0,25)ST |
100 |
500 |
5.8 |
53 |
|
20713 |
(3x2x0,50)ST |
100 |
500 |
8.2 |
100 |
|
21236 |
(4x2x0,25)ST |
100 |
500 |
6.9 |
80 |
|
23673 |
(6x2x0,50)ST |
500 |
11 |
205 |