Cross section min (mm2) | Cross section max (mm2) | Dynamic Installation | Static installation |
---|---|---|---|
1.50 | 300.00 | 6.0xØ |
These multi-rated flexible single core cables are UL and CSA approved, primarily designed for control cabinet wiring or installation in protective tubes. They can also be used indoors as fixed lay on bare walls, pipes, ducts, switchgears, or signal and control panels, within the UL-CSA standard specifications.
+5 °C +70 °C
static-40 °C +105 °C (AWM, CSA TEW, CSA AWM)
+90°C (MTW,HAR)
Occasional Flexing+5 °C +105 °C (AWM, CSA TEW, CSA AWM)
+90 °C (MTW, HAR)
600 V (UL/CSA TEW)
1000 V (RU/CSA AWM)
450/750 V (EU)
3000 V (UL)
2,5 kV (EU)
*
Test Voltage Reference* EN 50525-1, EN 50525-2-31
Group 1 |
|
---|---|
Conductor | CL5 Flexible. Bare Copper |
Insulation | PVC compound. |
Insulation Color | Various colours |
Fire performance
DIN VDE 0482-332-1-2
DIN EN 60332-1-2
VW-1 (UL)
FT1 (CSA)
IEC 60332-1-2
Oil performance
OIL RES I
60 °C UL 1063
EN 50290-2-22
TM54 CEI 20-34/0-1 4 h @ 70 °C oil IRM 902
Cross section mm2 |
1.50 (AWG16)
|
2.50 (AWG14)
|
4.00 (AWG12)
|
6.00 (AWG10)
|
10.00 (AWG08)
|
16.00 (AWG06)
|
25.00 (AWG04)
|
50.00 (AWG01)
|
52.00 (AWG1/0)
|
70.00 (AWG2/0)
|
95.00 (AWG3/0)
|
120.00 (AWG4/0)
|
150.00 (250KCMIL)
|
185.00 (350KCMIL)
|
240.00 (450KCMIL)
|
300.00 (550KCMIL)
|
|
|
Yellow RAL 1021 |
37482 | 38067 | 38080 | 38093 | 38106 | 38118 | 38126 | |||||||||
|
Green RAL 6018 |
37484 | 38069 | 38082 | 38095 | 38108 | 38120 | 38140 | 38726 | 38146 | 38151 | 38155 | |||||
|
White RAL 9010 - Red RAL 3000 |
37486 | 38071 | 38084 | 38099 | ||||||||||||
|
White RAL 9010 - Blue RAL 5015 |
37487 | 38072 | 38085 | 38097 | 38111 | 39299 | 38127 | |||||||||
|
White RAL 9010 - Orange RAL 2003 |
38693 | 38073 | 38694 | 38728 | 38729 | |||||||||||
|
White RAL 9010 - Yellow RAL 1021 |
38697 | 38086 | 38098 | |||||||||||||
|
Yellow RAL 1021 - Green RAL 6018 |
38134 | 38724 | 38142 | 38149 | 38698 | |||||||||||
|
Black RAL 9005 |
38135 | 38725 | 38143 | 38150 | 38154 | 38156 | 38157 | 38158 | 38159 | |||||||
|
Orange RAL 2003 |
38727 | 38147 | ||||||||||||||
Cross section mm2 |
1.50 (AWG16)
|
2.50 (AWG14)
|
4.00 (AWG12)
|
6.00 (AWG10)
|
10.00 (AWG08)
|
16.00 (AWG06)
|
25.00 (AWG04)
|
50.00 (AWG01)
|
52.00 (AWG1/0)
|
70.00 (AWG2/0)
|
95.00 (AWG3/0)
|
120.00 (AWG4/0)
|
150.00 (250KCMIL)
|
185.00 (350KCMIL)
|
240.00 (450KCMIL)
|
300.00 (550KCMIL)
|
|
cut |
|||||||||||||||||
rolls (m) |
100 | 100 | 100 | 100 | |||||||||||||
drums (m) |
915 | 610 | 305 | 305 | 100 | 100 | 100 | ||||||||||
diameter |
3.2 | 3.6 | 4.1 | 4.7 | 6.3 | 8 | 9.2 | 12.9 | 13.9 | 15 | 16.2 | 17.9 | 20.2 | 22.4 | 24.3 | 27.1 | |
cable weight |
23 | 34 | 48 | 67 | 119 | 187 | 291 | 580 | 615 | 780 | 1055 | 1175 | 1425 | 1735 | 2310 | 2950 |