Formation: (12G1,50)ST
(12xAWG16)ST
installation type: CABLE FOR DYNAMIC INSTALLATION ON DRAG CHAIN
category: MULTI CORE
standard/approval: CE/UL/CSA
shielding: SHIELDED
conductor | |
---|---|
material | Bare copper |
capillary diameter | - Extra-flexible (DIN VDE 0295, IEC 60228 or CEI 20-29) |
conductors number | 12 |
rated section | 1,50 mm² |
insulation | |
---|---|
material | Polyolefin |
colour | Black conductors with numbers from 1 to 11 + Green/Yellow. |
intermediate taping | |
---|---|
on make-up | Around the total assembly. |
material | Non-woven tape |
total shield | |
---|---|
on make-up | On the tape. |
material | Tinned copper |
shield shape | Braid shield |
coverage | >=85 % |
drain wire | Not available |
total taping | |
---|---|
on make-up | On the shield. |
material | Non-woven tape |
total sheath | |
---|---|
colour | Gray RAL 7001 |
diameter (mm) | 12.9±0.4 |
Marking | |
---|---|
Metric marking | P/N ***** TE.CO. E244280 - Fxx - cRUus - AWM STYLE 21179 90°C 1000V VW-1 - AWM I/II A/B 90°C 1000V FT1 - (nxXAWG) - O.R. FRX-ST® (nGY)SH - IEC 60332-1-2 - year/week - CE meter indication |
electrical features | |
---|---|
working voltage | 1000 V |
test voltage | 4000 V |
insulation resistance | >=1 Gohm/Km acc. to EN 50395 part.8 |
dynamic features | |
---|---|
minimum bending radius static installation | 4 times ø cable |
minimum bending radius dynamic installation | 7.5 times ø cable |
working temperature static installation | -40°C / +90°C |
working temperature dynamic installation | -5°C / +90°C |
travel speed | Up to 180 m/min |
acceleration/deceleration | Up to 10 m/sec² |
cable length inside chain | Up to 20 m |
chain length notes | (horizontal only) |
guaranteed cycles | Up to 5 Mio |
notes | The given data are meant to be restricted to the type of reference installation. For fixed installation is meant to be without any mechanica stress. For application in dynamic installation with very low temperatures, contact our technical department. |
approvals and standards | |
---|---|
reference standards | 1581, UL 758(UL); C22.2 n° 210(CSA); Referring to DIN VDE 0207,0285,0819 and 0295. |
ul csa approvals | RU E244280 AWM STYLE 21179 90°C 1000V CSA E244280 AWM I/II A/B 90°C 1000V |
fire behaviour | VW-1(UL); FT1(CSA); IEC 60332-1-2(EU); DIN VDE 0482-332-1-2; DIN EN 60 332-1-2; UL CABLE FLAME |
industrial oil resistance | 1581(UL); IEC 60811-404(EU); CEI EN 50363-4-1(EU); VDE 0473-811-404 |
halogen free | NO |
UV resistance | ASTM ASTM-D-2565-16; EN 50289-4-17(EU); ISO 4892-2 |
Customs code | |
---|---|
Customs-tariff number | 85444999 |
Made in | IT |
revision | |
---|---|
date | 25112020 |
number | 005 |
TE.CO. reserves the right to make some modifications to the products notwithstanding the basic technical characteristics. Unless otherwise stated, all indicated data are nominal. RAL colour is stated only as reference. TE.CO. Tecnologia Commerciale S.p.A. – Via Achille Grandi, 1 – 40013 Castel Maggiore (Bologna – Italia) – Tel +39 051 6047311 Web: www.tecoit.com – E-mail: sales@tecoit.com – Reg. Impr. Bologna e Codice Fiscale 03163100377 – P.IVA IT 01636081208. Subject to management and coordination activities handled by Pronos S.r.l.. All rights are reserved. The reproduction of any part of this document is not allowed without the written authorization of TE.CO. Tecnologia Commerciale S.p.A.. |