Formation: (2x2x0,34)ccST
(2x2xAWG22)ccST
installation type: CABLE FOR DYNAMIC INSTALLATION ON DRAG CHAIN
category: CANOPEN®
standard/approval: UL/CSA
shielding: SHIELDED
conductor | |
---|---|
material | Tinned copper |
capillary diameter | - Extra-flexible (DIN VDE 0295, IEC 60228 or CEI 20-29) |
conductors number | 4 |
rated section | 0,34 mm² |
insulation | |
---|---|
material | Polyolefin |
colour | White-Brown, Green-Yellow |
intermediate taping | |
---|---|
on make-up | Around the total assembly. |
material | Polyester tape |
total shield | |
---|---|
on make-up | On the tape. |
material | Tinned copper |
shield shape | Braid shield + drain wire |
coverage | >=85 % |
drain wire | Available |
drain material | Tinned copper |
drain rated section | 0,35 |
total taping | |
---|---|
on make-up | On the braid shield. |
material | Non-woven tape |
total sheath | |
---|---|
material | Polyurethane non-abrasive |
colour | Violet RAL 4001 |
diameter (mm) | 7.4±0.35 |
Marking | |
---|---|
Metric marking | P/N 17585 - TE.CO. E244280 - Fxx - cRUus - AWM STYLE 20236 80°C 30V - AWM I/II A/B 80°C 30V FT1 - (2x2xAWG22)H2 - O.R. PMXX-ST® CAN OPEN (2x2x0,34)H2 - year/week meter indication |
electrical features | |
---|---|
working voltage | 30 V |
test voltage | 500 V |
rated capacity | <=50 pF/m |
rated impedance | 120±10% ohm |
electrical resistance | <=55,4 ohm/km |
transmission speed | Up to 1Mbit/s |
attenuation | *** CAN OPEN® *** -------------------------------------------- ATTENUATION Frequency[MHz]/attenuation. std(dB/100m)/Attenuation. typica 0,1/0,7 - 0,5/1,3 - 1/1,9 - 4/4,6 . |
dynamic features | |
---|---|
minimum bending radius static installation | 6 times ø cable |
minimum bending radius dynamic installation | 10 times ø cable |
working temperature static installation | -50°C / +80°C |
working temperature dynamic installation | -40°C / +80°C |
travel speed | Up to 200 m/min |
acceleration/deceleration | Up to 10 m/sec² |
cable length inside chain | Up to 15 m |
chain length notes | (horizontal only) |
guaranteed cycles | Up to 5 Mio |
notes | The given data are meant to be restricted to the type of reference installation. For fixed installation is meant to be without any mechanica stress. For application in dynamic installation with very low temperatures, contact our technical department. |
approvals and standards | |
---|---|
reference standards | 1581, UL 758(UL); C22.2 n° 210(CSA); ISO 11898; RS 485 |
ul csa approvals | RU E244280 AWM STYLE 20236 80°C 30V CSA E244280 AWM I/II A/B 80°C 30V |
fire behaviour | FT1(CSA); IEC 60332-1-2(EU) HALOGEN FREE: IEC 60754-1(EU) |
industrial oil resistance | 1581(UL); IEC 60811-404(EU); CEI EN 50363-10-2(EU); IRM 902 |
halogen free | SI |
UV resistance | UV RESISTANT |
Customs code | |
---|---|
Customs-tariff number | 85444993 |
Made in | IT |
revision | |
---|---|
date | 24072018 |
number | 006 |
TE.CO. reserves the right to make some modifications to the products notwithstanding the basic technical characteristics. Unless otherwise stated, all indicated data are nominal. RAL colour is stated only as reference. TE.CO. Tecnologia Commerciale S.p.A. – Via Achille Grandi, 1 – 40013 Castel Maggiore (Bologna – Italia) – Tel +39 051 6047311 Web: www.tecoit.com – E-mail: sales@tecoit.com – Reg. Impr. Bologna e Codice Fiscale 03163100377 – P.IVA IT 01636081208. Subject to management and coordination activities handled by Pronos S.r.l.. All rights are reserved. The reproduction of any part of this document is not allowed without the written authorization of TE.CO. Tecnologia Commerciale S.p.A.. |